Panasonic TH-50PF9UK Computer Monitor User Manual


 
10
Connections
PC Input Terminals connection
Notes:
• Due to space limitations, occasionally you may have trouble connecting Mini D-sub 15P cable with ferrite core to PC
input Terminal.
• Computer signals which can be input are those with a horizontal scanning frequency of 15 to 110 kHz and vertical scanning
frequency of 48 to 120 Hz. (However, the image will not be displayed properly if the signals exceed 1,200 lines.)
• The display resolution is a maximum of 1,440 × 1,080 dots when the aspect mode is set to “NORMAL”, and 1,920 ×
1,080 dots when the aspect mode is set to “FULL”. If the display resolution exceeds these maximums, it may not be
possible to show ne detail with suf cient clarity.
• The PC input terminals are DDC1/2B-compatible. If the computer being connected is not DDC1/2B-compatible, you will
need to make setting changes to the computer at the time of connection.
• Some PC models cannot be connected to the set.
• There is no need to use an adapter for computers with DOS/V compatible Mini D-sub 15P terminal.
• The computer shown in the illustration is for example purposes only.
• Additional equipment and cables shown are not supplied with this set.
• Do not set the horizontal and vertical scanning frequencies for PC signals which are above or below the speci ed
frequency range.
• Component Input is possible with the pin 1, 2, 3 of the D-sub 15P Connector.
• Change the “COMPONENT/RGB-IN SELECT” setting in the “SET UP” menu to “COMPONENT”
(when COMPONENT connection) or “RGB” (when RGB signal connection). (see page 37)
Signal Names for Mini D-sub 15P Connector
Pin Layout for PC Input
Terminal
AUDIO
PC IN
COMPUTER
Conversion adapter
(if necessary)
Mini D-sub 15p
RGB
PC cable
Stereo plug
Audio
Connect a cable which matches
the audio output terminal on the computer.
1
678
3
9
45
10
15 14 13 12 11
2
Pin No.
Signal Name
Pin No.
Signal Name
Pin No.
Signal Name
1
R (P
R
/C
R
)
6
GND (Ground)
11
NC (not connected)
2
G (Y)
7
GND (Ground)
12
SDA
3
B (P
B
/C
B
)
8
GND (Ground)
13
HD/SYNC
4
NC (not connected)
9
NC (not connected)
14
VD
5
GND (Ground)
10
GND (Ground)
15
SCL