Paradyne 3166 DSU Network Card User Manual


 
SNMP MIB Objects
E-20
3166-A2-GB20-10November 1998
H testSendV54Up – Sends a V54 up code to the remote unit. Only supported
for the data ports.
H testSendV54Down – Sends a V54 down code to the remote unit. Only
supported for the data ports.
H testSendFT1Up – ends a FT1 up code to the remote unit. Only supported for
the data ports.
H testSendFT1Down – Sends a FT1 down code to the remote unit. Only
supported for the data ports.
Where these object identifiers are defined as follows:
H testLoopDTLB – OBJECT IDENTIFIER ::= [wellKnownTests 2]
H testMonQRSS – OBJECT IDENTIFIER ::= [wellKnownTests 3]
H testMon511 – OBJECT IDENTIFIER ::= [wellKnownTests 4]
H testSendQRSS – OBJECT IDENTIFIER ::= [wellKnownTests 5]
H testSend511 – OBJECT IDENTIFIER ::= [wellKnownTests 6]
H testSendV54Up – OBJECT IDENTIFIER ::= [wellKnownTests 7]
H testSendV54Down – OBJECT IDENTIFIER ::= [wellKnownTests 8]
H testSendFT1Up – OBJECT IDENTIFIER ::= [wellKnownTests 9]
H testSendFT1Down – OBJECT IDENTIFIER ::= [wellKnownTests 10]
Generic Interface Test Table – “ifExtnsTestResult” Object
(ifExtnsTestEntry 5)
This object contains the result of the most recently requested test. Only the
following values are supported by the DSU/CSU.
H none(1) – No test currently active.
H inProgress(3) – A test is currently in progress.
H notSupported(4) – The requested test is not supported.
H unAbleToRun(5) – The requested test cannot run due to the state of the unit.