Paradyne ENE2020-P Network Card User Manual


 
11
Power Solid
Green
ENE2020 is operational If the Power LED is not
illuminated, it is unlikely that
the ENE2020 is receiving
power and therefore none of
the LEDs will be illuminated.
10/100
Ethernet
Connection
100
Solid
Green
100 Mbps Ethernet
connection is
established
If the Ethernet 100 LED is
illuminated, the Ethernet Lnk
LED will also be illuminated.
No
Illumination
No 100 Mbps Ethernet
connection
If the Ethernet 100 LED
remains unlit but the Ethernet
Lnk LED is illuminated then a
connection has been
established at 10 Mbps rather
than 100 Mbps.
10/100
Ethernet
Connection
Act
Pulsing*
Amber
Standard operation Traffic is flowing without any
problems.
Solid
Amber
Heavy traffic
No
Illumination
No activity Either there is no Ethernet link
or a link exists but there is no
activity.
10/100
Ethernet
Connection
Lnk
Solid
Green
Ethernet connection is
established
If the Ethernet Lnk LED is
illuminated but not the
Ethernet 100 LED then a 10
Mbps connection has been
established. If the Ethernet
100 LED is also illuminated,
then a 100 Mbps connection
has been established.
No
Illumination
No Ethernet connection The Ethernet 100 and Act
LEDs will remain unlit by
default.
* A pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks
at a more rapid, less constant rate.
Table 6. LEDs (2 of 2)