General
Select General to configure a timeout period and duration for user-initiated loopbacks
and pattern tests, a primary and secondary clock source for the system, and a system
alarm relay.
General
Configuration Option Settings Default in [Bold]
Test Timeout [Enable], Disable
Test Duration (min) 1120 [10]
Primary Clock Source [Net1], DSX, Internal, DBM
Secondary Clock Source Net1, DSX, [Internal], DBM
System Alarm Relay Enable, [Disable]
Physical
Select Physical to configure the physical characteristics of each interface:
H Network
H Data Ports
H ISDN
Network
Select Network, then Physical to configure physical characteristics for the T1 network
interface.
Network
Configuration Option Settings Default in [Bold]
Line Framing Format D4, [ESF]
Line Coding Format AMI, [B8ZS]
Line Build Out (LBO) [0.0], 7.5, 15, 22.5
Bit Stuffing [62411], Disable
Transmit Timing [System], Interface
Network Initiated LLB [Enable], Disable
Network Initiated PLB [Enable], Disable
Network Initiated DCLB Disable, [V.54_&_ANSI]
ANSI Performance Report
Messages
Enable, [Disable]
Excessive Error Rate Threshold [10E-4], 10E-5, 10E-6, 10E-7, 10E-8, 10E-9
Circuit Identifier Text Field, [Clear]