Patton electronic 1002S Network Card User Manual


 
3.2.3 Connection Using Coax (BNC)
If you have the coax version of the Model 1002, simply connect the
BNC mating connectors to both modems.
APPENDIX A
PATTON MODEL 1002 SPECIFICATIONS
Transmission Format:Asynchronous
Transmit Line: 2 wire unconditioned twisted pair
or coaxial cable
Transmit Mode: Full or half duplex
Transmit Level: 0 dBm
Control Signals: DSR and DCD turn “ON” immediately after
the terminal raises DTR; CTS turns “ON”
immediately after the terminal raises RTS
Surge Protection: Compliant with IEC 801.5 level 2, 1kV
(Model 1002S Only)
Data Rate: 0 to 19.2 Kbps
Range: 2.0 miles @ 0 to 9600 bps
5.0 miles @ 19,200 bps
Power: No external power required, derives
required power from RS-232 input signals
Size: 2.20” x 1.75” x 0.75” (5.6 x 4.4 x 1.9 cm)
Temperature: 32° to 140°F
Humidity: 95% non-condensing
9 10