Patton electronic MODEL 1012AR Network Card User Manual


 
APPENDIX A
PATTON MODEL 1012AR SPECIFICATIONS
Transmission Format: Asynchronous, full duplex
Transmission Line: Two unconditioned twisted pair 19-26 AWG
Interface: EIA/TIA 561
Data Rates: 0 - 38.4 Kbps
Isolation: Minimum 1500 V RMS via custom
transformers
Surge Protection: 600W power dissipation at 1 mS and
response time of 1 pS
Control Signals: CTS follows RTS from the terminal (DTE);
DSR follows DTR from the terminal (DTE);
DCD indicates reception of carrier
RTS/CTS Delay: Approximately 35 mS
Connectors: 10 Pin RJ-45 on EIA/TIA-561 side; RJ-11
or 8 pin RJ-45 on line side
Power Supply: No external power required; uses power
from EIA data and control signals
Temperature Range: 0-60°C (32-140°F)
Altitude: 0-15,000 feet
Humidity: 5 to 95% noncondensing
Weight: 2 oz.
Dimensions: 2.66” x 2.10” x 0.73”
Copyright ©
Patton Electronics Company
All Rights Reserved
APPENDIX B
PATTON MODEL 1012AR BLOCK DIAGRAM
7 8
Distance Table (miles)
Data Wire Gauge
Rate 19 24 26
38,400 6.0 4.0 2.5
19,200 6.0 4.0 2.5
9,600 6.0 4.0 2.5
4,800 6.0 4.0 2.5
2,400 6.0 4.0 2.5
1,200 6.0 4.0 2.5