Patton electronic Model 3088/I Network Card User Manual


 
Configure the IP address
18
3088/I Getting Started Guide
2 • Initial configuration
Figure 3. DC Power Supply
Power-up indication
The Power and 100M Ethernet LEDs are lit while the RocketLink-G is powering up.
Configure the IP address
The RocketLink-G NTU is shipped with a factory-configured IP address assigned to the Ethernet LAN port
(green outline). The address is 192.168.200.10/24. In most cases, you must change the address to be on the
same subnet as your PC, as described in the procedures below. If you are not sure which IP address to use for
your installation, contact your network administrator.
Connect a PC and log in
Using the included combination RS-232/Ethernet cable and DB9-RJ45 adapter, connect a PC’s serial port to
the RocketLink-G’s Console port (red outline) (see figure 4).
Figure 4. Connecting RocketLink-G NTU to the PC’s serial port
There are no user-servicable parts in the power supply section of
the Model 3088/I. Fuse replacement should only be performed
by qualified service personnel. See Chapter 8, “Contacting Pat-
ton for assistance”
on page 64.
The interconnecting cables shall be acceptable for external use
and shall be rated for the proper application with respect to volt-
age, current, anticipated temperature, flammability, and
mechanical serviceability.
To Power
Supply Jack
To -48VDC
Source
-Vin
+Vin
SWITCHING POWER SUPPLY
MODEL : SYD1106-0505
INPUT : 36-60V 0.2A MAX
OUTPUT : +5V 1.0A
OUTPUT POWER : 5W MAX
S/N: G01234567890
MADE IN CHINA BY SUNNY
Black lead (-V)
Red lead (+V)
Barrel power connector
WARNING
CAUTION
MDI-X
LineEthernet
Power
Console
Connect to Console port
Serial port
PC with
terminal emulator