16 C2653M (6/07)
CONNECTIONS
Connections to the FT82011/FR82011 module are made on the rear panel of the unit (refer to Figure 6).
Figure 6. FT82011/FR82011 Module Connections
As illustrated in Figure 6, FT82011/FR82011 connections consist of the following:
• Power connection
NOTES:
– A 12 VDC or 24 VAC power supply can be used to power the module when used as a
stand-alone unit. A 12 VDC power supply is provided. If a 24 VAC power supply is used,
the power supply must be a Listed Direct Plug-In Power Unit marked as Class 2 and
rated as 24 VAC, 0.50 A (minimum output).
– In extreme temperature conditions, it is recommended that an industrial-rated outdoor
power supply be used.
• 10BASE-T/100BASE-TX connections
NOTES:
– Use Category 5e or a higher category of cable to connect to a 10BASE-T/100BASE-TX
port. Cable length must not exceed 328 feet (100 meters).
– The 10BASE-T/100BASE-TX port is an auto MDI/MDI-X port; therefore, either a straight-
through or crossover cable can be used. The port automatically detects the cable type
that is used. Refer to the Appendix for RJ-45 MDI/MDI-X pinout information.
FIBER OPTIC CABLE
10/100 NETWORK CABLE
POWER CONNECTION
FOR STAND-ALONE MODULE
POWER/ALARM CONNECTION
FOR RACK-MOUNTED MODULE