6 Pelco Manual C360M-I (11/99)
LIMIT STOP ADJUSTMENTS
To set pan limit stops, perform the following steps. Refer to Figure 5.
1. Loosen the pan limit stops.
2. Operate the scanner. Pan the unit to the right until the desired right pan limit is
reached.
3. Move the right pan limit stop until it touches the pan limit switch actuator. Push the
stop against the actuator until it clicks, indicating that the limit switch has opened.
Lock the stop in place.
4. Pan the unit to the desired left position. Adjust the left pan limit stop as described in
step 3.
5. Pan left and right to both limit stops and check for exact positioning. Tighten both stops
securely.
MAINTENANCE
The PS30A and PS30-24 require no lubrication, and the motors are both clutch and imped-
ance protected from overload.
SERVICE MANUAL
If you need to service your unit, obtain a service manual in one of the following ways:
• Go to Pelco’s web site at ftp://www.pelco.com and find service manual C360SM.
• Contact Pelco’s Literature Department and request service manual C360SM.
Figure 4. Control Unit Wiring Figure 5. Limit Adjustments
WARNING:
Do
not operate the
scanner without
limit stops. Do not attempt to
adjust the limit stops while
the unit is operating.
Personal injury or damage
to the unit may result. Do not
remove or reposition the
fixed limit stop on the
scanner. DAMAGE WILL
OCCUR.