Pelco VS5008 Switch User Manual


 
10 C808M-G (4/05)
4. Set the ALARM switch to the ON position.
NOTES:
With all channel switches set to the AUTO position, both monitors immediately switch to the alarmed channel and the associated LED
blinks. Multiple alarmed channels sequence every five seconds (VS5004) or three seconds (VS5008). The alarm has priority over the
MONITOR/AUTO/BYPASS switch settings.
If a channel switch is set to the MONITOR position, Monitor 1 switches to the alarmed channel while Monitor 2 displays the selected
(MONITOR) channel.
If a channel switch is set to the BYPASS position, Monitor 1 switches to that channel if it is alarmed.
Once triggered, the alarm remains on until the input condition is removed or the ALARM switch is moved to the OFF position.
When in the ALARM switch is set to the OFF position, all alarm inputs are ignored.
5. For channels with cameras connected to the video inputs, set the front panel switches to the AUTO position. All unconnected video inputs
should have their channel switch set to the BYPASS position.
NOTES:
With all channel switches in the AUTO position, both monitors sequence simultaneously.
Monitor 2 can be manually switched to any channel for continuous viewing by setting the desired channel’s switch to the MONITOR
position. If multiple channels are set to MONITOR, only the lowest numbered channel will be displayed. This does not affect the
sequencing for Monitor 1.
To remove a channel from the sequence, set the corresponding switch to the BYPASS position.
6. Connect the AC adapter to the 12 VAC input plug on the rear of the VS5004 or VS5008. Connect the transformer to a 120 VAC (VS5004 or
VS5008) or 230 VAC (VS5004/220 or VS5008/220) power source. After power up, the switcher will begin sequencing.
7. Using a screwdriver, adjust the DWELL interval control to the desired setting. This control adjusts the interval time from a minimum of
1 second to a maximum of 70 seconds nominal. To increase the interval, turn the control clockwise. To decrease the interval, turn the
control counterclockwise. The DWELL interval control is a precision 15-turn potentiometer. Each complete turn of this control will adjust the
time interval by approximately 4 to 5 seconds.
Figure 8.
VS5004 Conversion For Two-Monitor Operation
MON 1 MON 2
123
456
B4 V4
B3 V3 VG
B1 V1
B2 V2
H2
ORG
RED
BRN
MON1
B5
W/RED
GRN
H1
X2
X6
X1
X5 H5
BLU
G
X4
H3
X3
H6
J1 1
1
J2
PCB 90000101 COMPONENT SIDE
WIRE COLOR
BROWN
RED
ORANGE
YELLOW
GREEN
BLUE
WHITE/RED
CONNECT WIRE
TO PIN
B1
B2
B3
B4
B5
H5
X6
REMOVE WIRE
FROM PIN
H1
H2
H3
H4
H5
X6
G
TO CONVERT PC BOARD TO TWO MONITOR OPERATION,
REROUTE THE JUMPER WIRES AS FOLLOWS.