EasyTouch Load Center Installation Guide
Removing Electrical Conduit Knockouts
Before installing EasyTouch load center electrical conduit, read the following recommended
guidelines:
Determine the number of low and high voltage circuits being used in the EasyTouch load
center, the conduit size and runs needed based on the wire size, and the number of
conductors within the conduit. The EasyTouch load center conduit knockouts sizes are 1",
½" and ¾".
The EasyTouch load center conduit knockouts are located on the bottom and back of the
enclosure. Conduit knockouts sizes are 1", ½" and ¾". It is recommended to use 1” conduit
for the main AC power conductors. The 1" AC power conduit knockouts are located directly
under the main enclosure circuit breaker.
The EasyTouch load center enclosure must be located a minimum of 5 ft. from the inside
wall of pool or spa.
Remove the enclosure conduit knockouts as needed:
Low voltage raceway has three ¾" holes located on the left side of the enclosure.
High voltage compartment has four ¾" x 1” and eight ½" x ¾" conduit knockouts located
underneath the front of the enclosure.
¾" holes (3x) (low
voltage raceway)
1" conduit knockout (three #4 AWG
wires from main power supply
circuit breaker at house)
¾" x 1” conduit knockout (4x)
½" x ¾" conduit knockout (8x)
½" x ¾" conduit knockout (6x)
GFCI knockout
¾" x 1” conduit knockout