Pentair 8 and 4 Network Card User Manual


 
20
EasyTouch Load Center Installation Guide
Rewiring the IntelliChlor Transformer for 115 VAC
The IntelliChlor power supply transformer located in the EasyTouch load center can be wired for
220 VAC or 115 VAC. The IntelliChlor transformer is pre-wired at the factory for 220 VAC service.
To rewire the IntelliChlor transformer and EMI filter for 115 VAC:
WARNING - BEFORE REMOVING THE HIGH VOLTAGE COVER PANEL FROM THE
EASYTOUCH LOAD CENTER ENCLOSURE switch the main power OFF into the home at the
main circuit breaker box and also switch OFF the main power to the EasyTouch load center.
1. Switch the power off to the EasyTouch load center.
2. Unlatch the two front door latches and open the front door.
3. Remove the two retaining screws from the high voltage panel and remove the panel.
4. Rewire the Transformer and filter for 115 VAC as shown in the 115 VAC wiring diagram
below.
5. Install the high voltage panel and secure it with the two retaining screws.
6. Close the enclosure front door and secure with the latches.
FILTER
XFORMER
YEL
VIO
WHT
BRN
BLU
BRN
BLU
220VAC
BLK
FILTER
XFORMER
YEL
VIO
WHT
BRN
BLU
BRN
BLU
115VAC
BLK
NEUT
TO REWIRE
FOR 115VAC
INTELLICHLOR PRE-WIRED FOR 220 VAC
Retaining
screws
IntelliChlor
transformer
and filter
IntelliChlor transformer and filter wiring diagram
115 VAC