Perle Systems S-110PP-SFP Network Card User Manual


 
Perle PoE/PoE+ 10/100 Ethernet Media Converter
Installation Guide
9
detection
Down Down PSE disabled
These switches must be set in order to enable the power sourcing
function and to indicate the type of device detection required. If the
device type is unknown, the default should be used as per
IEEE802.3af/at standards.
Enabled: When enabled, the media converter will perform Power
Sourcing Equipment (PSE) functions as per IEEE802.3af (POE) or
802.3at-2009 (POE+) standards.
Disabled: When disabled the media converter will not perform
PSE functions.
PD Power Reset (Switch 6)
Switch Position Mode
Up (default) Disabled
Down Enabled
Disabled: When disabled, the loss of fiber link has no effect on
PSE power to the PD device.
Enabled: When enabled, if the media converter detects loss of link
on the fiber port it will turn off PSE output power to the PD device
connected to the copper port. After 2 seconds, the media
converter will restore power to the PD and the power will remain
on until the fiber link transitions from a link up to link down state.
Loopback Fiber (Switch 7)
Switch Position Mode
Up (default) Disabled
Down Enabled
Disabled: The loopback feature is disabled. This is default
position for normal operation. The switch must be set to this
position in order for data to pass through the media converter.
Enabled: This is a test mode. All data received on the receive
(RX) fiber connection is looped back to the transmit (TX) fiber
connection. The data link will be disabled; however power to the