Philips Kvaser LAPcan II Network Card User Manual


 
Kvaser LAPcan / LAPcan II Hardware Guide 7(19)
Kvaser AB, Mölndal, Sweden — www.kvaser.com
5 Technical data, Kvaser LAPcan and Kvaser LAPcan II
CAN channels 2 (CAN 2.0A and 2.0B active)
CAN Transceivers The transceivers are integrated into the DRVcans.
CAN Controllers Philips SJA 1000
Microcontroller Siemens SAB-C161O (16 MHz)
Baudrate 5 kbit/s ... 1 Mbit/s
Timestamp resolution 8 s
Error Frame Detection Yes, both channels
Error Frame Generation
Yes, both channels
Hardware requirements IBM PC AT or 100% compatible; PC-Card slot type II
or III
PC interface PC-Card Version 2.0 (PCMCIA) or compatible
Current consumption 110 mA for the Kvaser LAPcan plus the current of the
DRVcans
Software requirements Windows 95 / Windows NT 4.0 or later
Configuration Done by software (Plug & Play if OS supports it.)
Dimensions PC-Card type II (ca. 85 mm x 64 mm x 5 mm)
Operating temperature 0 ºC ... +55 ºC
Non-operating
temperature
-25 ºC ... +70 ºC
Relative Humidity 0% ... 85% (non condensing.)