Pico Communications E-15 Computer Hardware User Manual


 
Pico E-15 Hardware Reference
www.picocomputing.com
Pico Computing
(206) 283-2178
150 Nickerson Street. Suite 311
Seattle, WA 98109
31
CardBus Connector Pinout
1 GND Digital Ground
2 PCI_CAD0 Data / Address 0
3 PCI_CAD1 Data / Address 1
4 PCI_CAD3 Data / Address 3
5 PCI_CAD5 Data / Address 5
6 PCI_CAD7 Data / Address 7
7 P\C\I\_\C\C\B\E\0\ Byte Enable 0
8 PCI_CAD9 Data / Address 9
9 PCI_CAD11 Data / Address 11
10 PCI_CAD12 Data / Address 12
11 PCI_CAD14 Data / Address 14
12 P\C\I\_\C\C\B\E\1\ Byte Enable 1
13 PCI_CPAR Parity Even
14 P\C\I\_\C\P\E\R\R\ Parity Error
15 P\C\I\_\C\G\N\T\ Access Grant
16 P\C\I\_\C\I\N\T\ Interrupt Request
17 3.3V 3.3V Digital Supply
18 VPP No Connection
19 PCI_CCLK 33 MHz
20 P\C\I\_\C\I\R\D\Y\ Initiator Ready
21 P\C\I\_\C\C\B\E\2\ Byte Enable 2
22 PCI_CAD18 Data / Address 18
23 PCI_CAD20 Data / Address 20
24 PCI_CAD21 Data / Address 21
25 PCI_CAD22 Data / Address 22
26 PCI_CAD23 Data / Address 23
27 PCI_CAD24 Data / Address 24
28 PCI_CAD25 Data / Address 25
29 PCI_CAD26 Data / Address 26
30 PCI_CAD27 Data / Address 27
31 PCI_CAD29 Data / Address 29
32 PCI_RFU2 Reserved
33 PCI_CLKRUN Clock Request
34 GND Digital Ground
35 GND Digital Ground
36 PCI_DETECT CardBus Detect Shorted to 46
37 PCI_CAD2 Data / Address 2
38 PCI_CAD4 Data / Address 4
39 PCI_CAD6 Data / Address 6
40 PCI_RFU0 Reserved
41 PCI_CAD8 Data / Address 8
42 PCI_CAD10 Data / Address 10
43 PCI_DETECT CardBus Detect Shorted to 36
44 PCI_CAD13 Data / Address 13
45 PCI_CAD15 Data / Address 15
46 PCI_CAD16 Data / Address 16
47 PCI_RFU1 Reserved
48 P\C\I\_\C\B\L\O\C\K\ Bus Lock