8. TROUBLESHOOTING
net This chapter contains information to help you solve issues. If the Switch is not functioning properly, make sure the Ether
Switch was set up according to instructions in this manual.
The Link LED is not lit
heck the cable connection and remove duplex mode of the Switch.
Solution:
C
Some stations cannot talk to other stations located on the other port
Solution:
Please check the VLAN, port trunking function that may introduce this kind of problem.
Performance is bad
Solution:
Check the full duplex status of the Ethernet Switch. If the Ethernet Switch is set to full duplex and the partner is set to
the performance will be poor. half duplex, then
100Base-TX port link LED is lit, but the traffic is irregular
Solution:
Check that the
change duplex
attached device is not set to dedicate full duplex. Some devices use a physical or software switch to
modes. Auto-negotiation may not recognize this type of full-duplex setting.
Why the Switch doesn’t connect to the network
Solution:
Check the LNK/ACT LED on the switch Try another port on the Switch Make sure the cable is installed properly Mak
sure the cable is the right type Turn off the power. After a while, turn on power again.
e
Why I connect my PoE device to FNSW-1608PS / FGSW-1828PS and it cannot power on?
onnection from FNSW-1608PS / FGSW-1828PS (port 1 to
be an 8-wire UTP, Category 5 or above, EIA568 cable
Solution:
1. Please check the cable type of the c
port 8) to the other end. The cable should
within 100 meters. A cable with only 4-wire, short loop or over 100 meters, all will affect the
power supply.
2. Please check and assure the device that fully complied with IEEE 802.3af standard.
How to deal forgotten password situation of FNSW-1608PS / F
Solution:
GSW-1828PSS?
Please press Reset button at front panel for 5 seconds then the Web Smart PoE Switch will reset to
factory default mode(username and password: admin)