Parameters:
• Auth IP: Radius Authentication Server IP address (default)
• Auth Port: Radius Authentication Server Port
• Acct IP: Radius Account Server IP address
• Acct Port: Radius Account Server Port
• Backup Auth IP: Backup Radius Authentication Server IP address
• Backup Auth Port: Back Radius Authentication Server Port
• Backup Acct IP: Back Radius Account Server IP address
• Backup Acct Port: Back Radius Account Server Port
• Secret Key: The shared secret key with RADIUS Server
• Max Retry: The maximum retry times
• Response Time (sec): The maximum wait for response time from
RADIUS Server
• Auth Retry Interval (sec): The internal to resend the Authentication
packet to RADIUS Server.
• Acc Retry Interval (sec): The internal to resend the Account packet to
RADIUS Server.
• Switch Threshold: Switch to alternate RADIUS Server when failures are
occurred more than switch threshold.
• Auto Inactive: Auto inactive an unused or not
o Disable: Don’t auto inactive
o Prepaid User: Auto inactive prepaid user only
o Postpaid User: Auto inactive postpaid user only
o All User: Auto inactive all unused user
• Inactive prepaid: The minimum credit point threshold for a prepaid user
to be inactived
• Inactive Period: The max unaccess days for a postpaid user to be
inactived
• Charge Method: Billing charge method selection
o Point per Second: Point / calling rate = seconds
o Second per Point: Point * calling rate / charge point = seconds
• Auto Clean: Auto clean the inactive user