Polycom KWS8000 Server User Manual


 
KWS8000 Installation
1–3
Rack mounting Safety Precautions.
Ensure that the leveling jacks on the bottom of the rack are fully extended
to the floor with the full weight of the rack resting on them.
In a single rack installation, stabilizers should be attached to the rack.
In multiple rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from
the rack.
You should extend only one component at a time - extending two or more
simultaneously may cause the rack to become unstable.
Before you install the rails, determine the placement of each component in
the rack.
Install the heaviest components on the bottom of the rack first, and then
work up.
Always keep the rack’s trays and board’s closed when not servicing, to
maintain proper cooling.
The rack ambient temperature may rise beyond room ambient
temperature in a multi unit assembly, measures must be taken to ensure
the KWS8000 ambient temperature does not exceed the maximum
operating ambient temperature of 40 °Celsius.
To ensure ventilation always leave 2/3 U between the KWS8000 units any
other units mounted in the rack.
Always ensure proper rack earthing.
To Install the KWS8000 in a Rack
You can install the KWS8000 in a rack using one of the two following methods:
>>
Install the brackets supplied by the rack manufacturer on each side of the
rack on which the KWS 8000 is placed. Secure the system by fastening four
screws to the rack on the front panel.
>>
Install a shelf supplied by the rack manufacturer on top of which the
KWS8000 is placed. Secure the system by fastening four screws to the rack
on the front panel.