Polycom KIRK Wireless Server 8000 Installation Guide
1–6
2 Mount the wall hanger securely using four screws. Use rawlplugs,
expansion bolts or other appropriate fastening methods in relation to the
wall material.
3 Remove drilling dust, unpack the KWS8000, fit it into the wall hanger,
and then fasten the two front screws.
Figure 1-3 Fitting the kWS8000 into the wall hanger
Connecting the KWS8000 Cables
When the KWS8000 has been mounted, the cables can be connected.
Cable Safety Precautions
Before you connect the cables, ensure to take the following electrical safety
precautions.
• Always use an earthed socket for power.
• Use a power cord with protective earth (PE) connection suitable for the
country where it is being used and with the appropriate local approvals.
• If using a rack, always ensure proper rack earthing
• Power supply cables must be connected prior to connecting any interface
cables.