Raymarine M1500 Computer Monitor User Manual


 
11
The equipment is supplied from a separate battery from that used for engine start. Volt-
age drops below 10 V, and starter motor transients, can cause the equipment to reset.
This will not damage the equipment, but may cause the loss of some information and
may change the operating mode.
Raymarine specified cables are used. Cutting and rejoining these cables can compro-
mise EMC performance and must be avoided unless doing so is detailed in the instal-
lation manual.
If a suppression ferrite is attached to a cable, this ferrite should not be removed. If the
ferrite needs to be removed during installation it must be reassembled in the same
position.
Suppression Ferrites
The following illustration shows typical cable suppression ferrites used with Raymarine
equipment. Always use the ferrites supplied by Raymarine.
Connections to Other Equipment
If your Raymarine equipment is to be connected to other equipment using a cable not
supplied by Raymarine, a suppression ferrite MUST always be attached to the cable near
to the Raymarine unit.
Console Mounting - Display Dimensions
D3548-3
141.0 mm (5.55 in)
264 mm (10.4 in)
8.0 mm (0.315 in)
334.2 mm (13.16 in)
416.4 mm (16.4 in)
D6312-1
Weight: 10 kg (22 lbs)