Renesas HD74LVC1G66 Switch User Manual


 
HD74LVC1G66
Rev.3.00 Jul. 01, 2004 page 3 of 10
Recommended Operating Conditions
Item Symbol Min Max Unit Conditions
Supply voltage range V
CC
1.65 5.5 V
Control Input voltage range V
I
05.5V
Input/Output voltage range V
I/O
0V
CC
V
020
V
CC
= 1.65 to 1.95 V,
2.3 to 2.7 V
010 V
CC
= 3.0 to 3.6 V
Input transition rise or fall rate t / v
010
ns / V
V
CC
= 4.5 to 5.5 V
Operating free-air temperature T
a
–40 85 °C
Note: Unused or floating inputs must be held high or low.
Electrical Characteristics
Ta = –40 to 85°C
Item Symbol V
CC
(V) Min Typ Max Unit Test condition
1.65 to 1.95 V
CC
×0.65
2.3 to 2.7 V
CC
×0.7
3.0 to 3.6 V
CC
×0.7
V
IH
4.5 to 5.5 V
CC
×0.7
1.65 to 1.95 V
CC
×0.35
2.3 to 2.7 V
CC
×0.3
3.0 to 3.6 V
CC
×0.3
Input voltage
V
IL
4.5 to 5.5 V
CC
×0.3
V
1.65 13 30 I
S
= 4 mA
2.3 9 20 I
S
= 8 mA
3.0 7.5 15 I
S
= 24 mA
On–state switch
resistance
R
ON
4.5 5.5 10 I
S
= 32 mA
V
I
=V
CC
or GND
1.65 74.5 120 I
S
= 4 mA
2.3 20 30 I
S
= 8 mA
3.0 11.5 20 I
S
= 24 mA
Peak on resistance R
ON
(P)
4.5 7.5 15
I
S
= 32 mA
V
I
=V
CC
to GND
±1.0Off-state switch
leakage current
I
S (OFF)
5.5
±0.1*
1
µAV
I
= V
CC
and V
O
= GND or
V
I
= GND and V
O
= V
CC
,
V
C
= V
IL
±1.0On-state switch
leakage current
I
S (ON)
5.5
±0.1*
1
µAV
I
= V
CC
or GND, V
C
= V
IH
V
O
= Open
±1.0
Control input
current
I
IN
5.5
±0.1*
1
µAV
IN
= V
CC
or GND
10I
CC
5.5
1.0*
1
µAV
IN
= V
CC
or GNDQuiescent
supply current
I
CC
5.5 500 µAV
C
= V
CC
–0.6 V
Control input
capacitance
C
IC
5.0 3.0 pF
C
I/O(OFF)
5.0 6.0 Switch terminal
capacitance
C
I/O(ON)
5.0 13
pF
Note: 1. Ta = 25°C
(V) Min Typ Max Unit Test condition
0.7
0.7
0.7
1.65 to 1.95 V
CC
×
0.35
2.3 to 2.7 V
CC
×
0.3
3.0 to 3.6 V
CC
×
0.3
4.5 to 5.5 V
CC
×
0.3
V
1.65 13 30
9 20
7.5 15
4.5
5.5 10
1.65 74.5 120
2.3
20 30
3.0
11.5 20
4.5 7.5 15
±1.0
5.5