22
Table 2.6 Dialog Boxes for Setting Event Conditions
Function
Dialog Box
Address Bus
Condition
(Address)
Data Bus
Condition
(Data)
Bus State
Condition (Bus
Status)
Count
Condition
(Count)
Action
[Event
Condition 1]
Ch1 O O O O O
(B, T1, and P)
[Event
Condition 2]
Ch2 O O O X O
(B, T1, and P)
[Event
Condition 3]
Ch3 O X X X O
(B and T2)
[Event
Condition 4]
Ch4 O X X X O
(B and T3)
[Event
Condition 5]
Ch5 O X X X O
(B and T3)
[Event
Condition 6]
Ch6 O X X X O
(B and T2)
[Event
Condition 7]
Ch7 O X X X O
(B and T2)
[Event
Condition 8]
Ch8 O X X X O
(B and T2)
[Event
Condition 9]
Ch9 O X X X O
(B and T2)
[Event
Condition 10]
Ch10 O X X X O
(B and T2)
[Event
Condition 11]
Ch11 O
(reset point)
X X X O
(B and T2)
Notes: 1. O: Can be set in the dialog box.
X: Cannot be set in the dialog box.
2. For the Action item,
B: Setting a break is enabled.
T1: Setting the trace halt and acquisition conditions are enabled for the internal trace.
T2: Setting the trace halt is enabled for the internal trace.
T3: Setting the trace halt and point-to-point is enabled for the internal trace.
P: Setting a performance-measurement start or end condition is enabled.
The [Event Condition 11] dialog box is used to specify the count of [Event Condition 1] and
becomes a reset point when the sequential condition is specified.