Renesas M16C/62P Group Computer Hardware User Manual


 
Rev.1.00 2007.11.1
REC10B0002-0100
36
__StopSerialReceiving
Synopsis
<Stop reception>
Boolean __StopSerialReceiving(unsigned long data)
data Setup data
Description
Stops reception of serial communication.
[data]
For data, the following values can be set.
RAPI_COM1 UART0 RAPI_COM2 UART1
RAPI_COM3 UART2
Return value
If reception of serial communication was successfully stopped, RAPI_TRUE is
returned; if failed, RAPI_FALSE is returned.
Functionality
Serial I/O
Reference
__StartSerialReceiving
Remark
For the M16C SI/03 and SI/04, this API cannot be used.
If an undefined value is specified in the argument, operation of the API cannot be
guaranteed.
Program example
#include ”rapi_sif_m16c_62p”
void func( void )
{
/* Stop receiving data in serial communication */
__StopSerialReceiving ( RAPI_COM1 );
}