83
Return value
If the external interrupt specification is incorrect, RAPI_FALSE is returned; otherwise,
RAPI_TRUE is returned.
Functionality
External interrupt
Reference
__EnableInterrupt, __GetInterruptFlag, __ClearInterruptFlag
Remark
If an undefined value is specified in the first argument, operation of the API cannot
be guaranteed.
Program example
#include " rapi_interrupt_m16c_62p.h"
void IntFunc( void ){}
void func( void )
{
/* Set up _INT0 interrupt */
__SetInterrupt( RAPI_INT0|RAPI_INT_FALLING, 0, IntFunc );
}