Renesas M16C/62P Group Computer Hardware User Manual


 
Rev.1.00 2007.11.1
REC10B0002-0100
37
__StopSerialSending
Synopsis
<Stop transmission>
Boolean __StopSerialSending(unsigned long data)
data Setup data
Description
Stops transmission of serial communication.
[data]
For data, the following values can be set.
RAPI_COM1 UART0 RAPI_COM2 UART1
RAPI_COM3 UART2
Return value
If transmission of serial communication was successfully stopped, RAPI_TRUE is
returned; if failed, RAPI_FALSE is returned.
Functionality
Serial I/O
Reference
__StartSerialReceiving
Remark
For the M16C SI/03 and SI/04, this API cannot be used.
When operating in clock synchronous serial communication mode, data reception is
stopped at the same time by this API.
If an undefined value is specified in the argument, operation of the API cannot be
guaranteed.
Program example
#include ”rapi_sif_m16c_62p”
void func( void )
{
/* Stop sending data in serial communication */
__StopSerialSending ( RAPI_COM1 );
}