( 14 / 32 )
Note on BRK Instruction:
• BRK instruction cannot be used.
Note on Software Break and Hardware Break:
•A software break and a hardware break cannot be used simultaneously. If they are used
simultaneously, the emulation pod main unit may not work properly.
IMPORTANT
Note on Stack:
• This product uses up to 8 bytes for stack.
Notes on Using Address-match Interrupts:
• Do not set software breaks at the same addresses as address-match interrupts as the program may
run out of control.
• Do not set a hardware break within 4 instructions before an address at which an address-match
interrupt occurs. If you do set a hardware break in this range, the program will run out of control.
•When an address at which an address-match interrupt occurs is executed in one-step mode, the
program stops after executing the first instruction after returning from the address-match interrupt
processing.
Note on Software Reset:
• Do not use the software reset. It may not work properly.
Note on Watchdog Function:
• Debug functions such as a single step cannot be used while using the watchdog function. Only GO
command (program execution) is possible. To use other debug functions, disable the watchdog
function.
Note on Stop and Wait Modes:
•Do not perform step execution at addresses in the stop or wait mode. It may cause communication
errors.