Roland DIF-AT24 Network Card User Manual


 
9
Connections and settings
Sampling Frequency settings
Set the sampling frequency of your sequencer software, the VS-2400CD, and the UA-1000 to
the same setting (44.1 kHz or 48 kHz).
Master Clock settings
You'll also need to set the Master Clock for your sequencer software. For details on this setting, refer to the
owner's manual for your sequencer software.
Synchronization settings
Set the VS-2400CD's parameters as follows.
MMC settings
MTC settings
* Check the specifications of your sequencer software, and set your software and the VS-2400CD to the same
frame rate.
In order to synchronize operation with your sequencer software, you'll also need to make settings in the
sequencer software. For details on these settings, refer to the owner's manual for your sequencer software.
Master clock device VS-2400CD setting
DIF-AT24
MASTER CLK switch
VS-2400CD
PROJECT PARAMETER screen
MASTER CLOCL................INT
R-BUS
Sequencer software
PROJECT PARAMETER screen
MASTER CLOCL................R-BUS
ADAT
If using the sequencer software
as the MMC master
If using the VS-2400CD as the MMC master
MIDI PARAMETER screen
SysEx. Rx. Sw......................On
MMC MODE.......................SLAVE
MMC SOURCE...................R-BUS
MIDI PARAMETER screen
MIDI OUT/THRU .............Out
SysEx. Tx. Sw......................On
MMC MODE.......................MASTER
If using the sequencer software
as the MMC master
If using the VS-2400CD as the MMC master
SYNC PARAMETER screen
SYNC MODE......................EXT
EXT SYNC SOURCE..........R-BUS
FRAME RATE..................... Same setting as the
software.*
SYNC PARAMETER screen
SYNC MODE......................INT
FRAME RATE.....................Select the MTC
type.*
MIDI OUT SYNC Gen.......MTC
Settings