RuggedCom RS900GP Switch User Manual


 
3. Specifications
RuggedCom® RuggedSwitch™ 22 RS900GP Installation Guide Rev 100
3.7.2. IEEE 1613 Type Tests
IEEE Test IEEE 1613 Clause Description Test Levels
Enclosure Contact +/- 8kV
C37.90.3 9 ESD
Enclosure Air +/- 12kV
C37.90.2 8 Radiated RFI Enclosure ports 35 V/m
Signal ports
+/- 2kV
@ 2.5kHz
D.C. Power ports +/- 2kV
C37.90.1 7 Fast Transient
Earth ground ports +/- 2kV
Signal ports
2.2kV
common
mode @
1MHz
C37.90.1 7 Oscillatory
D.C. Power ports
2.2kV
common &
differential
mode @
1MHz
Signal ports
5 kV (Failsafe
Relay)
C37.90 6 H.V. Impulse
D.C. Power ports 5 kV
Signal ports
2kV
AC(Failsafe
Relay)
C37.90 6 Dielectric Strength
D.C. Power ports 1.2kV DC
Table 3.10. RS900GP IEEE 1613 Type Tests
If the unit contains copper ports the IEEE 1613 conformance is Class 1 (During
disturbance errors may occur but recovery is automatic).
If the unit contains all fiber ports the IEEE 1613 conformance is Class 2 (During
disturbance no errors will occur).
3.7.3. IEC Environmental Type Tests
Test Description Test Levels Severity Levels
IEC 60068-2-1 Cold Temperature Test Ad -40°C, 16 Hours N/A
IEC 60068-2-2 Dry Heat Test Bd +85°C, 16 Hours N/A
IEC 60068-2-30
Humidity (Damp
Heat, Cyclic)
Test Db
95% (non-condensing),
55°C, 6 cycles
N/A
IEC 60255-21-1 Vibration 2g @ (10-150) Hz Class 2
IEC 60255-21-2 Shock 30g @ 11 ms Class 2
Table 3.11. IEC Environmental Type Tests