Samsung 400PXn, 400PX, 460PXn, 460PX Computer Monitor User Manual


 
If the monitor is turned off at the scheduled download time, the system tries to turn on the monitor
and starts the download if the monitor is turned on within 3 minutes. Otherwise, the download will be
canceled.
1) Displays a list of the settings for downloading files to the monitor or deleting files.
(Displays the list for the currently connected monitor.)
2) Allows you to set the time for downloading files to the monitor or deleting files.
3) Allows you to specify the device and folder to which the downloaded files are saved.
4) Allows you to select the files from a server computer you want to download to your monitor.
5) Allows you to select the files you want to delete from your monitor.
6) Allows you to confirm and change the current download and deletion file selections.
4. Network Device
You can select a network device connected to the monitor. This is useful, especially if there are
multiple devices running on the PC.
z
Select a network device connecting to a monitor.
5. Monitor Update
You can update multiple monitors at the same time. This is useful when needing to update multiple
monitors at the same time.
When selecting a file to update and the update utility file (NK.bin) and clicking Update, the update
process is done in two steps. Download (stores the update file on the monitor) Update (installs
MagicNet).
When done, the monitor restarts automatically. If an error (wrong file) is detected during this process,
a warning message appears and the update process stops.
When the download is completed, make sure to keep the monitor turned on during the update. And, if
the output source is a PC, make sure the monitor-off function, if any, of the PC is not activated.
Otherwise MagicNet may not operate properly. If the monitor turns off during the update process,
contact our customer service.
For SyncMaster 320PXn/400P(T)Xn/460PXn, see Add/Remove Programs.
z Choose a monitor and file to update.
6. Monitor Model
If the monitor to the server is changed to SyncMaster 460Pn/400Pn, SyncMaster 320PXn/400P(T)
Xn/460PXn, SyncMaster 711ND or an integral model (mixed type), the server will be adjusted
according to the model.
Note that the supportable file formats, MDC and message-related functions will vary depending on the
selected monitor model.
z SyncMaster 400Pn/460Pn
z SyncMaster 711ND
z SyncMaster 400TXn
z SyncMaster 320PXn/400PXn/460PXn
z Combination
7. Save Schedule
Allows you to save all the schedules registered on all monitors to a server database.
If you shutdown and run the server again, the saved schedules will be imported.