Samsung SNS-100/400 Network Card User Manual


 
SNS-100/400 Network Server
14
RS-232C/SENSOR IN Connection
Connect the RS-232C/SENSOR IN terminal and use as shown below.
RS-485 I 422
RS-232C SENSOR IN RELAY OUT
MONITORVIDEO IN
AUDIO IN
AUDIO OUT
DC 12V
+-
TERMETHERMET
RS-485 I 422
RS-232C SENSOR IN RELAY OUT
MONITORVIDEO IN
AUDIO IN
AUDIO OUT
DC 12V
+-
TERMETHERMET
RS-232C SENSOR IN
SENSOR IN S1 S2 S3 S4 GND
1 Input
O - - - O
2 Input
- O - - O
3 Input
- - O - O
4 Input
- - - O O
1, 3 Input
O - O - O
1, 2, 3, 4 Input
O O O O O
For SNS-400
RS-485 I 422
RS-232C SENSOR IN RELAY OUT
MONITORVIDEO IN
AUDIO IN
AUDIO OUT
DC 12V
+-
TERMETHERMET
Input S1 Input S2
Input S3 Input S4
Input S1, S3
Input S1, S2, S3, S4
y In case of selecting Normal Open at setup menu:
In case of contact type, it is short and in case of active type, sensor input acts at “LOW” level.
y In case of selecting Normal Close at setup menu:
In case of contact type, it is open and in case of active type, sensor input acts at high impedance status(open collector).