BATTERY CHARGING - AC CONNECTIONS8.
This battery charger, with auto line voltage select function, is for use on 8.1
nominal 120 volt and 240 volt circuits.
DANGER – Never alter AC cord or plug provided – if it does not t the
outlet, have proper outlet installed by a qualied electrician. Improper
connection can result in a risk of an electric shock or re.
Recommended minimum AWG size for extension cords for battery 8.2
chargers: An extension cord up to 25 feet must be 12 AWG; up to 50 feet
must be 10 AWG and must have the proper 20 amp rated plug and recep-
tacle as shown below.
Grounding Methods8.3
This charger must be properly grounded. Make sure the AC outlet you are
plugging it into is properly grounded per local codes and regulations. If it
is not, have one installed by a qualied service person. Do not remove or
bypass the grounding pin on the plug or receptacle.