Seagate ST100FM0002 Computer Drive User Manual


 
PULSAR.2 SAS PRODUCT MANUAL, REV. C 19
6.0 PHYSICAL/ELECTRICAL SPECIFICATIONS
This section provides information relating to the physical and electrical characteristics of the drive.
6.1 POWER SPECIFICATIONS
The drive receives DC power (+5V and +12V) through the standard SAS interface.
6.1.1 Power consumption
Power requirements for the drives are listed in the tables beginning on page 21. Typical power measurements are based on an average of
drives tested, under nominal conditions, using +5V and +12V input voltage at 60°C ambient temperature.
Startup power
Startup power is measured from the time of power-on to the time that the drive reaches operating condition and can process media
access commands.
Peak operating mode
During peak operating mode, the drive is tested in various read and write access patterns to simulate the worst-case power consump-
tion.
Idle mode power
Idle mode power is measured with the drive powered up and ready for media access commands, with no media access commands
having been received from the host.
6.2 AC POWER REQUIREMENTS
None.