Seagate ST34501DC Computer Drive User Manual


 
18 Cheetah 4LP Installation Guide, Rev. B
Table 2. DC power requirements (Amps)
1
Measured with an average reading DC ammeter. Instanta-
neous +12V current peaks will exceed these values.
2
A –10% tolerance is permissible during initial start of the spin-
dle but must return to ±5% before reaching 10,000 RPM. The
±5% must be maintained after the drive signifies that its
power-up sequence has been completed and that the drive is
able to accept selection by the host initiator.
3
See the +12V current profile in the
Cheetah 4LP Product Man-
ual
(publication number 83329120).
4
This condition occurs when the Motor Start option is enabled
and the drive has not yet received a Start Motor command.
ST34501
N, W, WC models WD, DC models
+5V
8, 10
+12V
8
+5V
8
+12V
8
Voltage regulation
5
± 5% ± 5%
2
± 5% ± 5%
2
Max. start current
Peak DC
3, 6, 9
0.88 2.2 0.89 2.2
Delayed motor start
(max)
1, 4
0.81 0.08 0.72 0.08
Peak operating current
Typical DC
1
Maximum DC
1
Maximum (peak) AC
7
0.85
0.9
1.0
0.89
0.94
1.98
1.05
1.09
0.89
0.94
1.98