Seagate ST446452W Computer Drive User Manual


 
Elite 47 Installation Guide, Rev. B 17
neous peaks may exceed this value. These peaks should
measure 5 msec duration or less.
7
Minimum current loading for each supply voltage is not less
than 4% of the maximum operating current shown.
8
Use separate ground returns for +5V and +12V supplies.
9
Where power is provided to multiple drives from a common
supply, carefully consider individual-drive power requirements.
Where multiple units are powered on simultaneously, be sure
the peak starting current is available to each device.
10
No terminator power. See 11.7.3.3 in the
Elite 47 Product
Manual.
Table 3: Dimensions of the drive
Typical Maximum
inches mm inches mm
Height 3.25 82.6 3.268 83.0
Width 5.75 146.1 5.76 146.3
Depth 8.0 203.0 8.01 203.5
Weight 7.0 pounds (3.18 kilograms)