Sharp JW-50FL All in One Printer User Manual


 
9-31
Chapter 9: Message transfers
9
Ë Command
Ë Response
COM DSEG DADR
L DADRH LL LH DATA
COM RSLT DSEG DADR
L DADRH LL LH
Write same data to register (COM = 35(H))
[Format]
COM = 35(H)
DSEG = Segment (00 to 07, 10 to 2C(H)) See page 9-20.
DADRL, H = Byte address (0000(H) to FFFF(H)) See page 9-20.
LL,H = Data length (number of bytes)
DATA = Write data
[Function]
- Write the same data with the length shown by L, starting from DSEG, DADR.
[Execution condition]
- Write enable mode : Mode 1 and mode 2
- PC operation status : Stopping, operating
[Example]
- Write 4F(H) to register 19000 to 19003 (4 bytes).
Ë Command
Ë Response
35 00 00 0A 04 00 4F
35 00 00 00 0A 04 00
File number 0
File number 0
Top register
number 19000
Top register
number 19000
File address
0A00
(H) = 005000(8)
File address
0A00(H) = 005000(8)
Data
Data length