211
1.
In the SETTING window, select “20 ONLINE CONFIG”.
• The ONLINE CONFIG window will appear.
2.
Program each item as follows:
• TERMINAL No. (Use the numeric entry)
Terminal number (0 to 999999).
• CI SIGNAL (Use the selective entry)
Sensing of the CI signal
NON
SENSING
• LINE FORM (Use the selective entry)
Programming of the modem control
FULL: Full duplex system
HALF: Half duplex system
• BAUD RATE (Use the selective entry)
Transmission data rate
38400 bps 19200 bps 9600 bps
4800 bps 2400 bps
• START CODE (Use the numeric entry)
Start code (0 to 127)
• END CODE (Use the numeric entry)
End code (0 to 127)
• TIME OUT (Use the numeric entry)
Programming of the time-out time (1 to 255 sec.)
• AT OPEN STORE (Use the characteristic entry)
Description sent on AT command at the open store operation.
Up to 50 characters can be entered.
• AT CLOSE STOR (Use the characteristic entry)
Description sent on AT command at the close store operation.
Up to 50 characters can be entered.
Procedure
▼
On-line Configuration Programming
Use the following procedure to select the on-line configuration programming.
Please consult your dealer for more details.