Sharp XR-32X Projector User Manual


 
54
Remove the lamp unit.
Loosen the securing screws from the
lamp unit. Hold the lamp unit and pull it
in the direction of the arrow. At this time,
keep the lamp unit horizontal and do not
tilt it.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
Insert the new lamp unit.
•Press the lamp unit firmly into the lamp
unit compartment. Fasten the securing
screws.
Replace the lamp unit cover.
Align the tab on the lamp unit cover
(1) and place it while pressing the tab
(2) to close it. Then tighten the user ser-
vice screw (3) to secure the lamp unit
cover.
4
5
6
Connect the power cord.
Plug the power cord into the AC socket
of the projector.
Reset the lamp timer.
While simultaneously holding down
MENU/HELP, ENTER and R on the pro-
jector, press STANDBY/ON on the pro-
jector.
“LAMP 0000H” is displayed, indicating
that the lamp timer is reset.
Make sure to reset the lamp timer only when
replacing the lamp. If you reset the lamp timer
and continue to use the same lamp, this may
cause the lamp to become damaged or ex-
plode.
1
2
Info
AC socket
If the lamp unit and lamp unit cover are
not correctly installed, the power will not
turn on, even if the power cord is con-
nected to the projector.
Info
Regarding the Lamp (Continued)
Securing screws
ENTER button
MENU/HELP
button
R button
STANDBY/ON
button