5-57
ROUTING SWITCHER SYSTEM (E)
ODD
Field 1
EVEN
Field 2
ODD
Field 3
EVEN
Field 4
RS-422A
Switching Command Switching Executed
Switching Command Switching Executed
ODD
Field 1
EVEN
Field 2
ODD
Field 3
EVEN
Field 4
ODD
Field 1
EVEN
Field 2
ODD
Field 3
EVEN
Field 4
S-BUS
Switching Executed
Switching Executed
ODD
Field 1
EVEN
Field 2
ODD
Field 3
EVEN
Field 4
Switching Command
Switching Command
ODD
Field 1
EVEN
Field 2
ODD
Field 3
EVEN
Field 4
RS-422A
ODD
Field 1
EVEN
Field 2
ODD
Field 3
EVEN
Field 4
ODD
Field 1
EVEN
Field 2
ODD
Field 3
EVEN
Field 4
S-BUS
ODD
Field 1
EVEN
Field 2
ODD
Field 3
EVEN
Field 4
ODD
Field 5
Switching Command Switching Executed
Switching Command Switching Executed
Switching Command Switching Executed
Switching Command Switching Executed
ODD
Field 1
EVEN
Field 2
ODD
Field 3
EVEN
Field 4
RS-422A
ODD
Field 1
EVEN
Field 2
ODD
Field 3
EVEN
Field 4
ODD
Field 1
EVEN
Field 2
ODD
Field 3
EVEN
Field 4
S-BUS
ODD
Field 1
EVEN
Field 2
ODD
Field 3
EVEN
Field 4
Switching Command Switching Executed
Switching Command Switching Executed
Switching Command Switching Executed
Switching Command Switching Executed
5-8. Signal Switching Timing
5-8. Signal Switching Timing
For DVS-V3232B/V6464B and HDS-V3232, a SWITCHING FIELD which switch signals from the control terminal can
be set. The SWITCHING FIELD are set using menu item “Z” of the secondary station and any SWITCHING FIELD
mode (ODD, EVEN, FIELD, ASYNC) can be selected.
The signal switching timing depends on whether it is controlled by RS-422A or the S-BUS.
The following shows the timing charts of RS-422A and S-BUS for each SWITCHING FIELD mode.
..
..
. When SWITCHING FIELD “EVEN” is set
..
..
. When SWITCHING FIELD “ODD” is set
..
..
. When SWITCHING FIELD “FIELD” is set
..
..
. When SWITCHING FIELD “ASYNC” is set
The signals will be switched immediately after the switching command is received regardless of the control method and
protocol used.