2-3
ROUTING SWITCHER SYSTEM (E)
2-6. Protect Function
2-7. Secret Function
2-8. Crosspoint Disable Setting Function (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232)
2-9. Password Function (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232)
2-6. Protect Function
Function which protects the crosspoint set so that it cannot be released using other remote control units.
While the protect function is on, the destination of the crosspoint to be protected will be fixed. Once the
protect is set, it will not be released by any command, except those from the control terminal and the
control unit used to set it. The protect function can be set and released freely from the control terminal
connected to the primary station.
The control terminal also has a password function which allows only certain users to operate the system.
The protect function can be set in the menu item [C: SET DESTINATION NAME].
2-7. Secret Function
Function which “hides” certain sources from all control units to protect the crosspoint set so that it cannot
be switched.
Unlike the protect function that limits the destinations, the secret function limits the sources to protect
them from being selected by other control units.
The secret function can be set in the menu item [D: SET SOURCE NAME].
2-8. Crosspoint Disable Setting Function (DVS-V3232B/V6464B,
BKPF-R70 and HDS-V3232)
Function that limits the sources that can be selected for each destination. It can also be used to fix the area
of crosspoints selected so that only certain sources can be selected for certain destinations. This function
can be only used when a DVS-V3232B/V6464B, BKPF-R70 or HDS-V3232 is assigned as the primary
station.
This function can be set in the menu item [M: SET INHIBIT TABLE].
2-9. Password Function
(DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232)
The control terminal can set all configuration items of the routing switcher system. It therefore has a
password function which allows only certain users to operate it. The password can be set in the menu item
[P: CHANGE PASSWORD].