3434 (EN)
Specifications
Video processing
Capture range Horizontal rate: 15.6 to 80 kHz
Vertical rate: 48 to 120 Hz
Preset signal Input: 12 formats (See page
23(EN))
Video memory 1,152 × 1,152 × 24 bits (RGB total)
Sampling rate 12.5 to 40 MHz offset phase max.
(equivalent to 80 MHz sampling)
Panel system AC-type Plasma Display Panel
Display resolution 852 dots × 480 lines
Pixel pitch
1.08(horizontal) × 1.08(vertical) mm
(
1
⁄
16
×
1
⁄
16
inches)
Picture size
920 (horizontal) × 518 (vertical) mm
(36
1
⁄
4
× 20
1
⁄
2
inches)
Panel size 42-inch (diagonal 1,056 mm)
Inputs and Outputs
RGB1
R (R-Y)/ G (Y)/B (B-Y) IN
BNC-type (×3)
0.714 Vp-p/non-composite 75-ohm
(automatic termination)
1 Vp-p/composite 75-ohm
(automatic termination)
SYNC IN(HD/COMP, VD)
BNC-type (×2)
H (or composite) SYNC, V SYNC,
1 to 5 Vp-p high impedance
AUDIO IN (L, R) Phono jack (×2)
500 mVrms, high impedance
R (R-Y)/ G (Y)/B (B-Y) OUT
BNC-type (×3) Loop-through
SYNC OUT (HD/COMP, VD)
BNC-type (×2) Loop-through
H (or composite) SYNC,
V SYNC
AUDIO OUT (L, R)
Phono jack (×2) Loop-through
RGB2
RGB IN D-sub 15-pin
See “Pin assignment” on page
35(EN).
AUDIO IN (L, R) Phono jack (×2)
500 mVrms, high impedance
LINE (NTSC, PAL)
VIDEO IN BNC-type (×1)
Composite video, 1 Vp-p ±2 dB
sync negative, 75-ohm (automatic
termination)
Y/C IN Mini DIN 4-pin type (×1)
Y (luminance): 1 Vp-p ±2 dB sync
negative, 75-ohm (automatic
termination)
C (chrominance): Burst
0.286 Vp-p ±2 dB (NTSC),
75-ohm (automatic termination)
Burst 0.3 Vp-p ±2 dB (PAL)
75-ohm (automatic termination)
AUDIO IN (L, R) Phono jack (×2)
500 mVrms, high impedance
VIDEO OUT BNC-type (×1) Loop-through
Y/C OUT Mini DIN 4-pin type (×1) Loop-
through
AUDIO OUT (L, R) (Variable output)
Phono jack (×2) Loop-through
MONITOR OUT AUDIO (L, R)
Phono jack (×2)
Maximum 500 mVrms, high
impedance
CONTROL S (IN, OUT)
Mini jack (stereo) (×2)
5 Vp-p
SPEAKERS 6 to 16 ohms, 7 W + 7 W (when the
impedance is 8 ohms)
General
Power requirements
100 to 120 V AC, 50/60 Hz,
3.9 A/380 W
220 to 240 V AC, 50/60 Hz,
2.0 A/360 W
Operating conditions
Temperature: 0°C to 35°C (32°F to
95°F)
Humidity: 20% to 90% (no
condensation)
Atmospheric pressure: 700 to
1060 hPa