Sony RS-422A Switch User Manual


 
4-2
ROUTING SWITCHER SYSTEM (E)
4-2. Preliminary Information Before Installation
4-2. Preliminary Information Before Installation
The control area of each switcher when used as the primary station is as follows.
Model Input control Output control Level Remarks
area area management
DVS-V6464B 1 to 512 1 to 512 1 to 8 Expansion possible
DVS-A3232
DVS-RS1616
DVS-TC3232
DVS-V3232B 1 to 512 1 to 512 1 to 8 Expansion not possible
DVS-V1616
BVS-V3232
BVS-A3232
BKPF-R70
HDS-V3232
Example : DVS-V3232B and HDS-V3232 have 32 inputs and 32 outputs. But when one of them set the
primary station, it can control up to 512 inputs and 512 outputs using the cascading secondary
stations.
. Be sure to set a station number for each routing switcher and remote control unit installed.
Refer to the manuals of each unit for how to set the station number.
. In this manual, the input signal is called source, and the output signal destination.
. When using two or more BKS-R1607, BKS-R3209 or BKS-R3210 for a mother and daughter configu-
ration (combined system), it is necessary to set DVS-V3232B /V6464B, BKPF-R70 or HDS-V3232 as
the primary station.