Sony SDX-800V/R Computer Drive User Manual


 
6.Command Specification SPACE
6-102 SONY AIT-3Ex drive SDX-800V series Ver.1.1
Table 6-99: SPACE CHECK CONDITION results
Sense Data
Spacing Event
Detected
Valid Mark EOM Sense Key ASC/ASCQ Note
Blocks
File-marks
Set-marks
EOD
File-mark
Set-mark
EOD
BOT
Phy EOT
Set-mark
EOD
BOT
Phy.EOT
EOD
BOT
Phy.EOT
BOT
Phy.EOT
1
1
1
1
1
1
1
1
1
1
1
1
0
0
1
1
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
1
1
0
1
1
1
1
No Sense
No Sense
Blank Check
No Sense
Medium Error
No Sense
Blank Check
No Sense
Medium Error
Blank Check
No Sense
Medium Error
No Sense
Medium Error
File-mark Detected
Set-mark Detected
BOM/P Detected
EOM/P Detected
Set-mark Detected
BOM/P Detected
EOM/P Detected
BOM/P Detected
EOM/P Detected
BOM/P Detected
EOM/P Detected
a,b
a,b,d
b,e
b,f
b,g
a,b,d
b,e
b,f
b,g
b,e
b,f
b,g
c,f
c,g
Note a: The logical position is located on the EOM side of the mark if movement was in the forward direction and on
the BOM side of the mark if movement was in the reverse direction.
Note b: The Information field is set to the difference (residue) between the requested count and the actual number of
blocks, file marks, Set-marks, or spaced over.
Note c: The Information field will contain no residue count and therefore the Valid bit is not set.
Note d: The drive will only report that a Set-mark has been detected while spacing over blocks or File marks, if it has
been configured through MODE SELECT to Report Set-marks. Otherwise, the drive will continue the space
operation and the presence of the Set-mark will be transparent to the Host.
Note e: The tape is positioned such that a subsequent WRITE would append data after the last entity that has been
written to the tape before EOD.
Note f: The tape is physically positioned at BOM/P.
Note g: EOM is only reported when the physical EOM/P is encountered. The tape is physically positioned at EOM/P.