Sony SDX-800V/R Computer Drive User Manual


 
6.Command Specification INQUIR
Y
6-4 SONY AIT-3Ex drive SDX-800V series Ver.1.1
Table 6-2: Standard INQUIRY Data
Bit
Byte
7 6 5 4 3 2 1 0
0 Peripheral Qualifier Peripheral Device Type (01h)
1 RMB(1) Device-Type Modifier (0)
2 ISO Version (0) ECMA Version (0) ANSI-Approved Version (3)
3 AENC (0) TrmIOP Reserved(0) Response Data Format (2)
4 Additional Length (34h)
5 Reserved
6 Reserved Addr16 (1)
7 RelAdr (0) Reserved WB16 (1) Sync (1) Linked (0) Reserved CmdQ (0) SftRe (0)
8 (MSB) Vendor Identification
15 (SONY) (LSB)
16 (MSB) Product Identification
31 (SDX-800V) (LSB)
32 (MSB) Product Revision Level
35 (LSB)
36 Reserved
42 Reserved
43 Drive Mode
49 (DR-10)
50 Reserved
55 Reserved
56 Reserved CLOCKING (11b) QAS (0) IUS (0)
Peripheral Qualifier and Peripheral Device Type: These fields identify the device that is currently connected to the
logical unit. The drive is a single target, single logical unit device. The logical unit number is set to ZERO. Therefore,
the drive normally returns Peripheral Qualifier set to 000b the specified peripheral device type is currently connected
to this logical unit and Peripheral Device Type set to 01h sequential-access device .However, if the initiator requests
a logical unit number greater than ZERO, the drive returns Peripheral Qualifier set to 011b the target is not capable
of supporting a physical device on this logical unit and Peripheral Device Type set to 1Fh unknown device type .
RMB: The Removable Medium bit is one, indicating that the tape can be removed.
Device-Type Modifier: This is a seven-bit user defined code, set to 00h.
ISO Version: This field is ZERO, indicating that the drive does not necessarily comply with the ISO version of SCSI.
ECMA VERSION: This field is ZERO, indicating that the drive does not necessarily comply with the ECMA version of
SCSI.
ANSI Approved Version: This field indicates the implemented version of the ANSI version.
AENC: The drive does not support asynchronous event notification, so this field is ZERO.
TrmIOP: The drive does not support the Terminate I/O Process message, so this field is ZERO.
Response Data Format: This field is 2 indicating that the INQUIRY DATA format complies with the ANSI version of
SCSI-2.
Additional length: The additional length field specifies the length in bytes of the parameters, in this case, 31 bytes.
RelAdr: The drive does not support the Relative Addressing mode, so this bit is never set.
Wbus16: The drive supports 16-bit wide data transfers, so this bit is set.