Command Data Remark
ERST ? The following values are returned:
6th digit : Fan error
5th digit : Lamp error
4th digit : Temperature error
3rd digit : Cover open error
2nd digit : Filter error
1st digit : Other error
The following values are assigned to each digit :
0 : No error, or detection impossible
1 : Warning
2 : Error occurring
LAMP ? The following values are returned:
Lamp accumulative time (0 to 99999)
‘1’ when the lamp is on, ‘0’ when off.
Returns data for each lamp if there are multiple lamps.
INST ? The following values are returned:
Source No. of the input that can be switched
For source Nos., refer to the section on INPT.
NAME ? Returned value is a projector name (Max. 64 characters)
INF1 ? Returned value is a manufacturer name (Max. 32 characters)
INF2 ? Returned value is a model name (Max. 32 characters)
INFO ? Returned value is desired information (Max. 32 characters)
CLSS ? Returned value is the class of the corresponding PJLINK.
Speci cations
The speci cations of PJLink installed on the projector are as follows:
. Used port
4352
. Maximum number of controllers simultaneously connected
1 unit
. Authentication setting
Can be set on the Web screen.
The default settings are as follows:
Authentication setting : Enabled
Password : JBMIAProjectorLink