LMF Band controls:
Frequency Variable from 200Hz to 2.5kHz
Gain Variable by > ±20dB
‘Q’ Variable from 0.5 to 2.5 (may also vary with gain)
LF Band controls:
Frequency Variable from 40Hz to 600Hz
Gain Variable between ±16.5dB
‘Q’ 2.5 (on ‘ ’ setting)
The LF and HF bands have variable turnover frequency with switchable bell/shelving and selectable
response curves:
• Normal (‘E type’) curves with the ‘G-EQ’
switch OUT follow conventional cut or
boost characteristics.
• ‘G type’ curves with the ‘G-EQ’ switch IN,
have a modified slope with a degree of
overshoot/undershoot for increased
selectivity.
The two parametric bands have selectable characteristics which affect the relationship between frequency
bandwidth and gain:
• With the ‘G-EQ’ switch OUT, the frequency
bandwidth is constant at all gains.
• With the ‘G-EQ’ switch IN, the frequency
bandwidth reduces with increased gain,
thereby increasing the selectivity of the EQ
as the gain is increased.