Solid State Logic X-Logic Series Network Card User Manual


 
Page D-3
X-Rack Dynamics Module
D.3 Performance Specification
The following pages contain audio performance specification figures for the X-Rack Dynamics Module.
No other Solid State Logic products are covered by this document and the performance of other Solid State
Logic products can not be inferred from the data contained herein.
D.3.1 Measurement Conditions
For each set of figures on the following pages, the specific unit and test setup will be stated at the
beginning of that section. Any changes to the specified setup for any particular figure(s) will be detailed
beside the figures to which that difference applies.
D.3.2 Measurement References
Unless otherwise specified the references used in this specification are as follows:
Reference frequency: 1kHz
Reference level: 0dBu, where 0dBu 0.775V into any load
Source impedance of Test Set: 50
Input impedance of Test Set: 100k
All unweighted measurements are specified as 22Hz to 22kHz band limited RMS and are expressed in
units of dBu
All distortion measurements are specified with a 36dB/Octave low pass filter at 80kHz and are
expressed as a percentage
The onset of clipping (for headroom measurements) should be taken as 1% THD
Unless otherwise quoted all figures have a tolerance of ±0.5dB or 5%
All measurements are made with the operating level switch set for +4dBu
D.3.3 Compressor/Limiter
Controls:
Ratio (slope) Variable from 1 to infinity (limit)
Threshold Variable from +10dB to –30dB
Attack Time Normally auto sensing, switchable to 1mS
Release Variable from 0.1 to 4 seconds
The XLogic Channel unit Compressor/Limiter has two modes of signal detection, Peak and RMS. As their
names suggest these modes of detection either act on peaks of the incoming signals or on their RMS levels.
This gives two very different modes of compression and limiting with Peak Mode giving far more
dramatic compression characteristics.
D.3.4 Expander/Gate
Controls:
Range Variable from 0 to 40dB
Threshold Variable from –30dB to +10dB
Attack Time Normally auto-sensing, switchable to 150µs
Hold Time Variable from 0 to 4 seconds
Release Time Variable from 0.1 to 4 seconds
The side chain signal can be sourced either from the signal feeding the dynamic or the external Key input.
Filters and/or Equaliser can be inserted in the sidechain.
LED meters independently indicate amount of compression and expansion.