StorageTek SCSI-3 Switch User Manual


 
FCP and SES Commands
3-6 8946121402
Switch Page
If requested using the Send Diagnostic or Receive Diagnostic Result command, the
SESD returns the response shown in Table 3-10.
2 (MSB)
Page Length = 7 (LSB)
3
4 00h
5 80h
6 81h
7 82h
8 83h
9 84h
10 85h
Table 3-10 Switch Page Format
Byte/Bit Field # Access 7 6 5 4 3 2 1 0
0 na na Page Code = 80h
1 na na Reserved
2 .. 3 na na Page Length = 404
4 .. 7 na na swValid
8 .. 71 0 ro Current_Date (in ASCII text)
72 .. 135 1 ro Boot_Date (in ASCII text)
136 .. 199 2 ro Firmware_Last_Updated_Date (in ASCII text)
200 .. 263 3 ro FLASH_Last_Updated_Date (in ASCII text)
264 .. 327 4 ro Boot_PROM_Last_Updated_Date (in ASCII text)
328 .. 391 5 ro Firmware_Version_Information (in ASCII text)
392 .. 395 6 ro Switch_Operational_Status
396 .. 399 7 rw Switch_Administrative_Status
400 .. 403 8 ro Diagnostics_Result
404 .. 407 9 ro Number_of_Sensors
Note: na is not available, ro is read only and rw is read/write
Table 3-9 Page Code 0 Format – Supported Diagnostic Pages (Continued)
Byte/Bit 7 6 5 4 3 2 1 0