StorageTek SCSI-3 Switch User Manual


 
FCP and SES Commands
3-10 8946121402
Name Server Local Table Page
If requested using the Send Diagnostic or Receive Diagnostic Result command, the
SESD returns the following response as shown in Table 3-15.
108 .. 111 24 ro swFCPortTxMcasts[0]
112 .. 115 25 ro
swFCPortLipIns
116 .. 119 26 ro
swFCPortLipOuts
120 .. 123 27 ro
swFCPortLipLastAlpa
.. ... more instances of swFCPortEntry (swValidity .. swFCPortTxMcasts) if applicable ...
(
n-4
)..(
n-1
) 0 - 27 ro swFCPortLipLastAlpa[
i-1
]
Table 3-15 Format of Name Server Local Table Page
Byte/Bit Field # Access 7 6 5 4 3 2 1 0
0 na na Page Code = 85h
1 na na Reserved
2 .. 3 na na Page Length =
n
- 3
4 .. 7 na na swNumEntries =
i–
Note that each entry consists of swValidity[0]
field through field 10.
8 .. 11 na ro
swValidity[0]
12 .. 15 0 ro
swNsIndex[0]
16 .. 19 1 ro
swNsPortType[0]
20 .. 23 2 ro
swNsPortID[0]
24 .. 31 3 ro
swNsPortName[0]
32 .. 287 4 ro
swNsPortSymbolicName[0]
288 .. 295 5 ro
swNsNodeName[0]
296 .. 551 6 ro
swNsNodeSymbolicName[0]
552 .. 559 7 ro
swNsInitialProcessInitiator[0]
560 .. 575 8 ro
swNsClassOfServices[0]
576 .. 579 9 ro
swNsClassOfServices[0]
580 .. 643 10 ro
swNsFc4Types[0]
... ... more instances of swNsLocalEntry (swValidity..swNsFc4Types) if applicable ...
(
n-4
)..(
n-1
) 0 - 10 ro swNsFc4Types[
i-1
]
Table 3-14 Fibre Channel Port Table Page Format (Continued)
Byte/Bit Field # Access 7 6 5 4 3 2 1 0