Sun Microsystems 805-1759-10 Computer Hardware User Manual


 
8 Sun FastEthernet PCI Adapter Installation and User’s Guide July 1997
3. Use the show-devs command to list the system devices.
You should see output, similiar the following example, displayed on your screen.
SUNW,hme identifies the Sun FastEthernet PCI Adapter Ethernet device.
network identifies the motherboard network interface.
If these devices are not listed, check that the adapter is properly seated and reinstall
the adapter, if necessary.
Diagnostics Testing
For Sun FastEthernet PCI Adapter diagnostic testing, see Appendix A, “Using the
selftest Diagnostics,” and refer to the SunVTS User’s Guide.
ok show-devs
/SUNW,ffb@1e,0
/SUNW,UltraSPARC-II@0,0
/counter-timer@1f,1c00
/pci@1f,2000
/pci@1f,4000
/virtual-memory
/memory@0,60000000
/aliases
/options
/openprom
/chosen
/packages
/pci@1f,4000/SUNW,hme@4,1
/pci@1f,4000/pci108e,1000@4
/pci@1f,4000/pci@2
/pci@1f,4000/scsi@3
/pci@1f,4000/network@1,1
/pci@1f,4000/ebus@1
/pci@1f,4000/scsi@3/tape
/pci@1f,4000/scsi@3/disk