Chapter 3 Sun StorEdge A3500/A3500FC Configurations 3-17
3.4 2x7 Cables and Connections
This section contains information about SCSI, FC-AL, and power connections for
two StorEdge A3500 controller modules, or two StorEdge A3500FC controller
modules, with seven StorEdge D1000 disk arrays.
3.4.1 SCSI Cable Lengths
The following tables show the lengths of each SCSI cable connected to the drive
connections on the respective controller modules.
The inboard IN/OUT connectors on each of the top four disk arrays are connected
using a 0.2m/0.65 ft SCSI jumper cable, part number 530-1883.
The inboard IN/OUT connectors on the bottom three disk arrays are terminated
with differential SCSI terminators, part number 150-1890.
TABLE 3-8 Controller Module A (2x7) Cables
SCSI Port Number Cable Length Part Number
1 0.8m/2.6 ft 530-1884
2 0.8m/2.6 ft 530-1884
3 0.8m/2.6 ft 530-1884
4 2.0m/6.5 ft 530-1885
5 2.0m/6.5 ft 530-1885
TABLE 3-9 Controller Module B (2x7)
SCSI Port Number Cable Length Part Number
1 2.0m/6.5 ft 530-1885
2 0.8m/2.6 ft 530-1884
3 0.8m/2.6 ft 530-1884
4 2.0m/6.5 ft 530-1885
5 2.0m/6.5 ft 530-1885